1. Check if the air source has air
2. Is the pressure detected by the pressure solenoid valve adjusted high
3. Is there a disconnection in the connecting line
4. The air pressure solenoid valve is broken
When there is a lack of air pressure, first check the pressure gauge to see if it is really a lack of air pressure. If it is really a lack of air pressure or a lack of air, check the air source.
If there is gas and an alarm is triggered, you can check if the pressure solenoid valve has set the pressure too high. Generally, it is enough to set it to 4MPA, but if it is too high, it can be reduced to 4MPA.
If the air pressure solenoid valve is not set too high, you can short circuit the signals X21 and+24V connected to the air pressure solenoid valve to see the diagnostic input signal in the system (FANUC system is the "signal" X3.0 in "PMC maintenance").
The new generation system is equipped with a diagnostic signal I016. Is there a signal change? If there is a signal change, it may be a problem with the air pressure solenoid valve. You can try replacing it with a new one.
·Can stamping hardware processing can only be stamped with simple parts? ·What are the types of the five -axis processing center? ·The content and scope of the workers operated by the vertical processing center? ·stable product quality, reasonable layout, reduce waste and improve material utilization. ·The Rise and Influence of CNC Technology in Modern Manufacturing Industry · The division of CNC machining processes can generally be carried out according to the following met ·What are the metal die casting processes ·Does the main axis of the large CNC processing center affect the speed of operation? ·The technical advantage of CNC ·How to process the mold for mold processing center