1. Check if the air source has air
2. Is the pressure detected by the pressure solenoid valve adjusted high
3. Is there a disconnection in the connecting line
4. The air pressure solenoid valve is broken
When there is a lack of air pressure, first check the pressure gauge to see if it is really a lack of air pressure. If it is really a lack of air pressure or a lack of air, check the air source.
If there is gas and an alarm is triggered, you can check if the pressure solenoid valve has set the pressure too high. Generally, it is enough to set it to 4MPA, but if it is too high, it can be reduced to 4MPA.
If the air pressure solenoid valve is not set too high, you can short circuit the signals X21 and+24V connected to the air pressure solenoid valve to see the diagnostic input signal in the system (FANUC system is the "signal" X3.0 in "PMC maintenance").
The new generation system is equipped with a diagnostic signal I016. Is there a signal change? If there is a signal change, it may be a problem with the air pressure solenoid valve. You can try replacing it with a new one.
·machining center · CNC machining - a powerful partner for efficient manufacturing ·What is the application scope of metal aluminum die-casting so wide ·What is the machining principle of CNC horizontal machining center for single arm drilling and tappi ·How to reduce the error of each link of auto hardware parts ·What are the aspects of the determination of the workpiece and folder? ·What are the process documents of CNC Dragon Gate Processing Center? ·Method of checking stamping shots during hardware processing ·What parts should be paid attention to during the processing of network switches · CNC Machining Machining, which is effective to reduce production costs